background image
395
HC-RELAYS
MINIATURE RELAY
FOR WIDER APPLICATIONS
VDE
1c, 2c, 4c
HCE Amber Relays
mm
inch
27.2
1.071
35.2
1.386
20.8
.819
27.2
1.071
35.2
1.386
20.8
.819
FEATURES
窶「 Extra long life 窶 Min. 10
8
mechanical operations (DC type)
窶「 4 contact arrangements
4 Form C (for 5 A 250 V AC),
3 Form C (for 7 A 250 V AC),
2 Form C (for 7 A 250 V AC),
1 Form C (for 10 A 250 V AC)
窶「 Applicable to low to high level loads (100
ツオ
A to 10A)
窶「 Amber sealed types available
窶「 Bifurcated contact types available as HC4D
SPECIFICATIONS
Contacts
Coil
Remarks
* Speciャ…ations will vary with foreign standards certiャ…ation ratings.
*
1
Detection current: 10 mA
*
2
Excluding contact bounce time
*
3
Half-wave pulse of sine wave: 11ms; detection time: 10
ツオ
s
*
4
Half-wave pulse of sine wave: 6ms
*
5
Detection time: 10
ツオ
s
*
6
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Characteristics
Arrangement
1 Form C 2 Form C 3 Form C
4 Form C
Initial current resistance, max.
(By voltage drop 6 V DC 1 A)
30 m
邃ヲ
Contact material
Gold-ャBshed silver alloy
Gold-clad
silver nickel
Rating
(resistive)
Nominal
switching capacity
10 A
250 V AC
7 A
250 V AC
7 A
250 V AC
5 A
250 V AC
Max. switching
power
2,500 VA
1,750 VA
1,750 VA
1,250 VA
Max. switching
voltage
250 V AC
Max. switching
current
10 A
7 A
7 A
5 A
Nominal operating power
AC (50Hz): 1.3VA, AC (60Hz): 1.2 VA
DC:0.9 to 1.1W
Max. operating speed
20 cpm (at max. rating)
Initial insulation resistance
Min. 1,000 MW at 500 V DC
Initial
breakdown
voltage*
1
Between open contacts
700 Vrms for 1 min.
Between contact sets
700 Vrms for 1 min.
Between contact and coil
2,000 Vrms for 1 min.
Operate time*
2
(at nominal voltage)
(at 20ツーC)
Approx. 10 ms
(DC, AC type)
Release time (without diode)*
2
(at nominal voltage) (at 20ツーC)
Approx. 5 ms (DC type)
Approx. 10 ms (AC type)
Temperature rise, max. (at 70
ツー
C)
(at nominal voltage)
80
ツー
C
Shock resistance
Functional*
3
Min. 196 m/s
2
{20 G}
Destructive*
4
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
5
10 to 55 Hz at double
amplitude of 1 mm
Destructive
10 to 55 Hz at double
amplitude of 2 mm
Conditions for operation,
transport and storage*
6
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
窶50
ツー
C to +70
ツー
C
窶58
ツー
F to +158
ツー
F
Humidity
5 to 85% R.H.
Unit weight
Approx. 30g
1.06 oz
Expected life (min. operations)
Electrical (at 20 cpm)
Voltage
125 V AC
250 V AC
30 V DC
Expected life
Load
Resistive
(cos
= 1)
Inductive
(cos
]
0.4)
Resistive
(cos
= 1)
Inductive
(cos
]
0.4)
Resistive
Inductive
HC1
(1 Form C)
Current
10A
5A
10A
3A
2
10
5
7A
3A
7A
2.5A
3A
1A
5
10
5
5A
2A
5A
1.5A
1
10
6
HC2
(2 Form C)
Current
7A
3.5A
7A
2A
2
10
5
5A
2.5A
5A
1.5A
3A
0.6A
5
10
5
3A
1.5A
3A
1A
1
10
6
HC3
(3 Form C)
Current
7A
7A
1
10
5
3.5A
2A
2
10
5
5A
5A
3A
0.4A
5
10
5
HC4
(4 Form C)
Current
5A
2A
5A
1A
2
10
5
3A
1A
3A
0.8A
3A
0.4A
5
10
5
2A
0.5A
2A
0.4A
1
10
6
Mechanical life (at 180 cpm)
DC type: 10
8
, AC type: 5
10
7
background image
HC
396
TYPICAL APPLICATIONS
Transportation, power station control
equipment, refrigerators, building control
equipment, ofャ…e machines, coin operat-
ed machines, amusement devices, medi-
cal equipment, etc.
ORDERING INFORMATION
EX. HC
4
D
H
AC 240V
Contact arrangement
1: 1 Form C
2: 2 Form C
3: 3 Form C
4: 4 Form C
Nil: Standard type
D: Bifurcated contact type
(HC4D only. See Page 400.)
K: Latching relay type
(HC2K only. See Page 401.)
H: Plug-in
HP: PC board terminal
HTM: Top mounting
HL: Light emitting diode
wired, plug-in
HPL: Light emitting
diode wired, PC
board
AC 6, 12, 24, 48, 120/240 V
DC 6, 12, 24, 48, 110 V
Type classifications
Terminal arrangement
Coil voltage
Notes:
1. When ordering VDE recognized types, add suffix VDE.
2. HC3 (3 Form C) series are not approved by VDE.
3. AC 48 V type is not available for LED wiring.
4. Standard packing Carton: 20 pcs.; Case: 200 pcs.
5. UL/CSA approved type is standard.
COIL DATA
(Common for Standard, Amber sealed and Bifurcated contact types)
DC Type at 20
ツー
C
68
ツー
F
AC Types (50/60 Hz) at 60 Hz, 20
ツー
C
68
ツー
F
Coil voltage,
V DC
Pick-up voltage,
V DC (max.)
Drop-out voltage,
V DC (min.)
Max. allowable
voltage,
V DC
Coil resistance,
邃ヲ
(
ツア
10%)
Nominal coil
current,
mA (
ツア
10%)
Operating power, W
Nominal
Minimum
6
4.8
0.6
6.6
40
150
0.9
0.58
12
9.6
1.2
13.2
160
75
0.9
0.58
24
19.2
2.4
26.4
650
37
0.9
0.58
48
38.4
4.8
52.8
2,600
18.5
0.9
0.58
110
88.0
11.0
121.0
10,000
10
1.0
0.64
Coil voltage,
V AC
Pick-up voltage,
V AC (max.)
Drop-out voltage,
V AC (min.)
Max. allowable
voltage,
V AC
Nominal coil
current,
mA (
ツア
20%)
Operating power, VA
Nominal
Minimum
6
4.8
1.8
6.6
200
1.20
0.77
12
9.6
3.6
13.2
100
24
19.2
7.2
26.4
50
48
38.4
14.4
52.8
25
110/120
96
36
132
10.9/11.9
220/240
176.0
66.0
264.0
6.0/6.5
NOTES:
1. The range of coil current is
ツア
15% for AC
(60 Hz), and
ツア
10% for DC, at 20
ツー
C.
2. The relay is applicable to the range of
80 % to 110% of the nominal coil voltage.
However, it is recommended that the relay
be used in the range of 85% to 110% to
take temporary voltage variations into
consideration.
3. The coil resistance of DC types is the
measured value at a coil temperature of
20
ツー
C. Please compensate coil resistance
by
ツア
0.4% for each degree centigrade coil
temperature change.
4. All AC 240 V types are rated for double
coil voltages, both AC 220 V and AC 240 V.
5. For use with 220 V or 240 V DC, con-
nect a resistor as suggested in the chart
below, in series with the 110 V DC relay.
Voltage
1 Form C, 2 Form C,
3 Form C, 4 Form C
220 V DC
11 k
邃ヲ
(5 W)
240 V DC
13 k
邃ヲ
(5 W)
background image
HC
397
DIMENSIONS
(Common for standard, Amber sealed and Bifurcated contact (4C only) types)
Plug-in type
HC1-H (1 Form C)
HC2-H (2 Form C)
HC3-H (3 Form C)
HC4-H (4 Form C)
General tolerance:
ツア
0.2
ツア
.008
20.8
.819
0.6
.024
6.4
.252
0.5
.020
4.41
.174
4.06
.160
6.35
.250
6.35
.250
4.45
.175
13.35
.526
2.54
.100
1
.039
27.2
1.071
35.2
1.386
1.7
.067
1.7
.067
20.8
.819
0.6
.024
6.4
.252
0.5
.020
4.41
.174
4.06
.160
6.35
.250
6.35
.250
13.35
.526
2.54
.100
1
.039
27.2
1.071
35.2
1.386
1.7
.067
1.7
.067
20.8
.819
0.6
.024
6.4
.252
0.5
.020
4.41
.174
4.06
.160
6.35
.250
6.35
.250
13.35
.526
2.54
.100
1
.039
27.2
1.071
35.2
1.386
1.7
.067
1.7
.067
20.8
.819
0.6
.024
6.4
.252
0.5
.020
4.41
.174
4.06
.160
6.35
.250
6.35
.250
4.45
.175
13.35
.526
2.54
.100
1
.039
27.2
1.071
35.2
1.386
1.7
.067
1.7
.067
mm
inch
PC board type
HC4-H (4 Form C)
General tolerance:
ツア
0.2
ツア
.008
20.8
.819
0.6
.024
3.5
.138
0.5
.020
4.41
.174
4.06
.160
6.35
.250
6.35
.250
4.45
.175
13.35
.526
1.5
.059
1.5
.059
1
.039
27.2
1.071
35.2
1.386
1.7
.067
1.7
.067
Dimensions of HC1-HP,
HC2-HP, HC3-HP are the
same as those of plug-in type
except shapes of terminals.
PC board pattern
(Copper-side view)
1c
2c
4.1
.161
16.8
.661
10.4
.409
8.9
.350
4.45
.175
13.35
.526
5-2 dia.
5-.079 dia.
4.1
.161
16.8
.661
10.4
.409
13.35
.526
8-2 dia.
8-.079 dia.
3c
4c
Tolerance:
ツア
0.1
ツア
.004
4.1
.161
16.8
.661
10.4
.409
13.35
.526
11-2 dia.
11-.079 dia.
4.1
.161
16.8
.661
10.4
.409
8.9
.350
4.45
.175
13.35
.526
14-2 dia.
14-.079 dia.
Note: Special PC terminal with 0.9 mm (
.035 inch
) width available with
sufャ』 "-31".
Schematic
(bottom view)
HC1-H, HC1-HP (1 Form C)
LED AC type
LED DC type
HC2-H, HC2-HP (2 Form C)
LED AC type
LED DC type
HC3-H, HC3-HP (3 Form C)
LED AC type
LED DC type
HC4-H, HC4-HP (4 Form C)
LED AC type
LED DC type
2
7
12
14
13
7
12
14
2
13
(
竏シ
)
(
竏シ
)
2
7
12
14
13
(
)
(
+
)
1
4
8
12
14
5
9
13
14
13
(
竏シ
)
(
竏シ
)
1
4
8
12
5
9
14
13
(
)
(
+
)
1
4
8
12
5
9
1
14
4
7
2
5
8
3
6
9
13
14
13
(
竏シ
)
(
竏シ
)
1
4
7
2
5
8
3
6
9
14
13
(
)
(
+
)
1
4
7
2
5
8
3
6
9
1
14
5
9
2
6
10
3
7
11
4
8
12
13
14
13
(
竏シ
)
(
竏シ
)
1
5
9
2
6
10
3
7
11
4
8
12
14
13
(
)
(
+
)
1
5
9
2
6
10
3
7
11
4
8
12
background image
HC
398
REFERENCE DATA
1. Life curve
Load: 250 V AC resistive load
2. Switching capacity range
3. H
2
S gas test
2
4
6
8
10
100
200
300
400
500
5,000
10,000
1c
2c
3c
4c
Load current, A
Life,
10
4
times
Mechanical life (DC type)
Mechanical life (AC type)
(250 V AC cos
= 1)
10mA
100
10
250
1A
1mA
7A
5A 10A
HC1c
HC4c
HC2c, 3c
AC current
AC voltage, V
10
1
10m
邃ヲ
100m
邃ヲ
1
邃ヲ
10
邃ヲ
100
邃ヲ
20
50 100
Exposure time, Hrs.
200 500 1000 2000 5000
Standard HC relay
HCE Amber relay
Gas density:
2 to 5 ppm
Temperature: 40
ツー
C
Humidity: 90% RH
Contact resistance
4. Coil temperature rise
Measured portion: Inside the coil Note: When
the nominal voltage is applied to AC 120 or 240
V coil types respectively, the ャ“ures of coil tem-
perature rise increase by approx. 10 degrees to
the ones shown on each graph.
HC1 AC coil
Ambient temperature: 25
ツー
C
77
ツー
F
HC2 AC coil
Ambient temperature: 30
ツー
C