background image
3.5 - 37
3.5
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Positive Regulators In Hermetic
Surface Mount Package
HERMETIC SURFACE MOUNT FIXED VOLTAGE POSITIVE
REGULATORS APPROVED TO DESC DRAWINGS
FEATURES
• Hermetic Surface Mount Package
• Output Voltages: +5V, +12V, +15V
• Output Voltages Set Internally To ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Hi-Rel Screening Available
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed surface
mount package. All protective features are designed into the circuit including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are +5V, +12V, and +15V.
These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number
Omnirel Part Number
5962-8778201 NX
OM1805NMM
5962-8777601 NX
OM1812NMM
5962-8855301 NX
OM1815NMM
4 11 R0
OM1815NMM
OM1805NMM
OM1812NMM
background image
3.5 - 38
3.5
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 5 Volt
V
IN
= 10V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
V
OUT
T
A
= 25°C
4.92
5.08
V
V
IN
= 7.5V to 20V
4.85
5.15
V
I
O
= 5mA to 1.0A, P < 15 W
Line Regulation
V
RLINE
V
IN
= 7.5V to 20V
5
mV
(Note 1)
12
mV
(Note 4)
V
IN
= 8.0V to 12V
4
mV
10
mV
Load Regulation
V
RLOAD
I
O
= 5mA to 1.5 Amp
12
mV
(Note 1)
I
O
= 5mA to 1.0Amp
25
mV
I
O
= 250mA to 750 mA
6
mV
15
mV
Standby Current Drain
I
SCD
6
mA
6.5
mA
Standby Current Drain
I
SCD
V
IN
= 7.5V to 20V
0.8
mA
Change With Line
(Line)
Standby Current Drain
I
SCD
I
O
= 5mA to 1000mA
0.5
mA
Change With Load
(Load)
Dropout Voltage
V
DO
T
A
= 25°C,
V
OUT
= 100mV, I
O
=
1.0A
2.5
V
Peak Output Current
I
O (pk)
T
A
= 25°C
1.5
3.3
A
Short Circuit Current
I
DS
V
IN
= 35V
1.2
A
(Note 2)
2.8
A
Ripple Rejection
V
IN
f =120 Hz,
V
IN
= 10V
68
dB
V
OUT
(Note 3)
60
dB
Output Noise Voltage
N
O
T
A
= 25°C, f =10 Hz to 100KHz
40
µV/V
(Note 3)
RMS
Long Term Stability
V
OUT
T
A
= 25°C, t = 1000 hrs.
75
mV
(Note 3)
t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
ABSOLUTE MAXIMUM RATINGS
@ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range
. . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C
T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance
θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
θ
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120°C/W
a
background image
3.5 - 39
3.5
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 12 Volt
V
IN
= 19V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
V
OUT
T
A
= 25°C
11.88
12.12
V
V
IN
= 14.5V to 27V
11.64
12.36
V
I
O
= 5mA to 1.0 A, P < 15W
Line Regulation
V
RLINE
V
IN
= 14.5V to 27V
18
mV
(Note 1)
50
mV
(Note 4)
V
IN
= 16V to 22V
9
mV
30
mV
Load Regulation
V
RLOAD
I
O
= 5mA to 1.5 Amp
32
mV
(Note 1)
I
O
= 5mA to 1.0 Amp
60
mV
I
O
= 250mA to 750 mA
20
mV
40
mV
Standby Current Drain
I
SCD
6.0
mA
6.5
mA
Standby Current Drain
I
SCD
V
IN
= 15V to 30V
0.8
mA
Change With Line
(Line)
Standby Current Drain
I
SCD
I
O
= 5mA to 1000mA
0.5
mA
Change With Load
(Load)
Dropout Voltage
V
DO
V
OUT
= 100mV, I
O
=
1.0A
2.5
V
Peak Output Current
I
O (pk)
T
A
= 25°C
1.5
3.3
A
Short Circuit Current
I
DS
V
IN
= 35V
1.2
A
(Note 2)
2.8
A
Ripple Rejection
V
IN
f =120 Hz,
V
IN
= 10V
61
dB
V
OUT
(Note 3)
54
dB
Output Noise Voltage
N
O
T
A
= 25°C, f =10 Hz to 100KHz
40
µV/V
(Note 3)
RMS
Long Term Stability
V
OUT
T
A
= 25°C, t = 1000 hrs.
120
mV
(Note 3)
t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
.140
.415
.157
.015
.140
.140
.075
.075
.062
.375
.030
MIN.
MECHANICAL OUTLINE
CONNECTION
Pin 1 Input
Pin 2 Output
Pin 3 Ground
1
2
3
background image
OM1805NMM - OM1815NMM
3.5
ELECTRICAL CHARACTERISTICS 15 Volt
V
IN
= 23V, I
o
= 500mA, -55°C ≤ T
A
≤ 125°C (unless otherwise specified)
Parameter
Symbol
Test Conditions
Min.
Max.
Unit
Output Voltage
V
OUT
T
A
= 25°C
14.8
15.2
V
V
IN
= 18.5V to 30V
14.6
15.4
V
I
O
= 5mA to 1.0 A, P < 15W
Line Regulation
V
RLINE
V
IN
= 17.5V to 30V
20
mV
(Note 1)
50
mV
(Note 4)
V
IN
= 20V to 26V
15
mV
25
mV
Load Regulation
V
RLOAD
I
O
= 5mA to 1.5 Amp
35
mV
(Note 1)
I
O
= 5mA to 1.0 Amp
75
mV
I
O
= 250mA to 750 mA
21
mV
45
mV
Standby Current Drain
I
SCD
6.0
mA
6.5
mA
Standby Current Drain
I
SCD
V
IN
= 18.5V to 30V
0.8
mA
Change With Line
(Line)
Standby Current Drain
I
SCD
I
O
= 5mA to 1000mA
0.5
mA
Change With Load
(Load)
Dropout Voltage
V
DO
T
A
= 25°C,
V
OUT
= 100mV, I
O
=
1.0A
2.5
V
Peak Output Current
I
O (pk)
T
A
= 25°C
1.5
3.3
A
Short Circuit Current
I
DS
V
IN
= 35V
1.2
A
(Note 2)
2.8
A
Ripple Rejection
V
IN
f =120 Hz,
V
IN
= 10V
54
dB
V
OUT
(Note 3)
52
dB
Output Noise Voltage
N
O
T
A
= 25°C, f =10 Hz to 100KHz
40
µV/V
(Note 3)
RMS
Long Term Stability
V
OUT
T
A
= 25°C, t = 1000 hrs.
150
mV
(Note 3)
t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.5
3
2.5
2
1.5
1
0.5
0
0
5
1 0
1 5
2 0
2 5
3 0
3 5
V
OUT
= 100mV
T
j
= -55°C
T
j
= 25°C
T
j
= 150°C
Input To Output Differential (V)
2.5
2
1.5
1
0.5
0
-75-50 -25
0
2 5 5 0 7 5 1 0 0 1 2 51 5 0
V
OUT
= 100MV
I
OUT
= 0A
I
OUT
= 500mA
I
OUT
= 1A
Junction Temperature (°C)
1 0 0
8 0
6 0
4 0
2 0
0
1 0
1 0 0
1k
10k
V
OUT
= 5V
V
IN
- V = 8V
DC
+3.5V
rms
I
OUT
= 1A
T
j
= 25°C
Frequency (Hz)
TYPICAL PERFORMANCE CHARACTERISTICS
Ripple Rejection (dB)
Output Current (A)